electrical device

1.250A/10KV/6 heads/5 positions/three phase 2.frequency :50HZ,60HZ 3.Open holeof box :30 4.disk tape 5.electrical device 1. This switch  for power transformer was designed together by the related factories organised by Shenyang Transformer research Institute. 2.It is...
cooling blower for transformer

cooling blower for transformer

1.Cooling blower diameter of wheel 420 2.Total length of the blower 90 3.Capacity of transformer matched 50-100KVA 1.When the cooling blower is used for cooling the dry-type transformer, the blowers should be at both sides of the coil, the cold air is directly blowing into the...
release pressure valve

release pressure valve

1.opening pressure: 25Kpa 2.Effective oil jetting ccaliber: 25mm 3.Mounting method: screw mounting 4.pressure valve  1.This series of pressure control valves applies to the pressure protection of the oil boxes of the products of oil-immersed transformer fully-seales...
transformer electrical device

transformer electrical device

1.250A/10KV/6 heads/5 positions/three phase 2.frequency :50HZ,60HZ 3.Open holeof box :30 4.disk tape 5.electrical device 1. This switch  for power transformer was designed together by the related factories organised by Shenyang Transformer research Institute. 2.It is...
load switch controller

load switch controller

1.Controller working voltage:220V 2.Signal voltage:100-400V 3.Control accuracy:0.5-0.9 1.Together with the OLTC and the load voltage regulating transformers, this type of controller can realize the voltage regulating transformers' by hand and automatic controlling.2. The...
cooling blower

cooling blower

1.Cooling blower diameter of wheel 470 2.Total length of the blower 155 3.Capacity of transformer matched 800-1600KVA 1.When the cooling blower is used for cooling the dry-type transformer, the blowers should be at both sides of the coil, the cold air is directly blowing into...
dry type transformer temperature controller

dry type transformer temperature controller

1. three phase roving/top phase 2.output over temperature alarm 3.directly 6one phase blower 4.temperature controller Features & Specification of Basic ModelJL-BWD3K130ABThe transformer useWTemperature moduleDResistance type3Temperature measurement points...
load switch controller

load switch controller

1.Controller working voltage:220V 2.Signal voltage:100-400V 3.Control accuracy:0.5-0.9 1.Together with the OLTC and the load voltage regulating transformers, this type of controller can realize the voltage regulating transformers' by hand and automatic controlling.2. The...
dry-type transformer temperature controller

dry-type transformer temperature controller

1. three phase roving/top phase 2.output over temperature alarm 3.directly 6one phase blower 4.temperature controller Features & Specification of Basic ModelJL-BWD3K130ABThe transformer useWTemperature moduleDResistance type3Temperature measurement points...
load switch controller

load switch controller

1.JLK-716 type 2. OLTC controller 3. special used for the load transformers 4.controller working voltage220V±10% 50HZ signal voltage 100-400v / 50hz control accuracy 0.5-9.9%(adjustable) control error ±1 operating time...